HAG Base Hot Boilers - 5 LACKS KCAL/HR
This is indirect hot air boiler mainly used for air heating process requirement. Capacity starts from 100000 kcal/hour to
2000000 kcal/hour& above at 250’C as per customer’s requirement.
This equipment consisting of 4 paths flew gas system.
Radiant path constructed from SS 410 of shell to shell and another 2nd, 3rd &5th pass constructed from ERW IS 1239 tubes.
Furnace made from MS structure and high aluminium bricks line, high grade CI casted fire bars equipment is fully insulated with high
grade density glass wool.
System is controlled through the control panel with simulation of ID & FD fans maintain the air temperature and smoke temperature
at prefix set value.
TECHNICAL SPECIFICATION HOT AIR BOILER -5.0 LK KCAL –HR | ||
Model | Model_IV | |
Product | IN DIRECT HOR AIR GENERATOR- SOLID FUEL FIRE | |
Capacity | 5 LACKS KCAL- HR | |
No of PASS | 5 PASS – 2PASS SS &3PASS MSTUBE TYPE HEADER TYPE - VERTICAL MODEL | |
POWER | Centrifugal CA blower | 30HP |
ID FAN | 10HP | |
FD FAN | 3 HP | |
TOTAL | 43 HP | |
WORKING TEMPERATURE | 120 –130 C | |
CA FAN AIR VOLUME AND PRESSURE | 25000 CU.MTR @ 200 MM PRESSURE | |
FUEL | LIGNITE – 180 KG HR (GCV 4000 KCAL/ HR) | |
| WOOD – 300 KG HR (GCV 2400 KCAL/ HR) | |
BOILER EFFICENCY | 70 % | |
(ALL SPECIFICATION AND DESIGN RIGHT RESERVED BY -OPTYTECH.) |