Corn Flakes Dryer - HAG Base

Corn Flakes Dryer - HAG Base
Corn Flakes Dryer - HAG Base
Product Code : CFD H1 (250KG/HR)
Product Description

Corn Flakes Dryer - HAG Base

 


DRYER TECHNICAL SPECIFICATION
Model Model – I _FULLY INSULATED
Product CORN FLACKS (MAKKA POHA)
Capacity 250 KG\HR

POWER
Centrifugal Exhaust blower 3.7 KW (3.7KW X 1 NOS.)
Cooling Blower 1.5 KW
Conveyor Gear drive 1.1 KW (0.37 KW X 3 NOS.)
Material mixer drive 1.5 KW (0.75 KW X 2 NOS.)
Oscillator feeder drive 0.75 KW (0.75 KW x 1 NOS)
Total 8.55 KW
Working temperature 70 – 80 C
Heating media req HOT AIR GENERATOR 1.0 LK KCAL-HR
Drying Bed Area (SS conv Width x Length) 1.5 MTR x 2. 5 MTR + 2.5MTR Cond Belt
No of Layer 5 Layers
Dryer Efficiency 70.00%
Over all space require for dryer
( Length x Width x Height _ in mtr)
7.5 MTR X 2.75 MTR X 4 MTR
(ALL SPECIFICATION AND DESIGN RIGHT RESERVED BY -OPTYTECH.)










HOT AIR BOILER TECHNICAL SPECIFICATION
Model Model_II
Product HOT AIR BOILER
Capacity 1.0 LACKS KCAL HR

POWER
Centrifugal CA blower 5.5 KW
Furnace Id Fan 1.5 KW
Furnace Fd fan 0.75 KW
Total 7.75 KW
Working temperature 100 –120 C
Fuel consumption 60 kg- wood ( GCV 2400 )
No of PASS 5 pass
Dryer Efficiency 70.00%
Over all space require for dryer
( Length x Width x Height _ in mtr)
3 MTR X 3 MTR X 4.5 MTR

Corn Flakes Dryer - HAG Base

 


DRYER TECHNICAL SPECIFICATION
Model Model – I _FULLY INSULATED
Product CORN FLACKS (MAKKA POHA)
Capacity 250 KG\HR

POWER
Centrifugal Exhaust blower 3.7 KW (3.7KW X 1 NOS.)
Cooling Blower 1.5 KW
Conveyor Gear drive 1.1 KW (0.37 KW X 3 NOS.)
Material mixer drive 1.5 KW (0.75 KW X 2 NOS.)
Oscillator feeder drive 0.75 KW (0.75 KW x 1 NOS)
Total 8.55 KW
Working temperature 70 – 80 C
Heating media req HOT AIR GENERATOR 1.0 LK KCAL-HR
Drying Bed Area (SS conv Width x Length) 1.5 MTR x 2. 5 MTR + 2.5MTR Cond Belt
No of Layer 5 Layers
Dryer Efficiency 70.00%
Over all space require for dryer
( Length x Width x Height _ in mtr)
7.5 MTR X 2.75 MTR X 4 MTR
(ALL SPECIFICATION AND DESIGN RIGHT RESERVED BY -OPTYTECH.)










HOT AIR BOILER TECHNICAL SPECIFICATION
Model Model_II
Product HOT AIR BOILER
Capacity 1.0 LACKS KCAL HR

POWER
Centrifugal CA blower 5.5 KW
Furnace Id Fan 1.5 KW
Furnace Fd fan 0.75 KW
Total 7.75 KW
Working temperature 100 –120 C
Fuel consumption 60 kg- wood ( GCV 2400 )
No of PASS 5 pass
Dryer Efficiency 70.00%
Over all space require for dryer
( Length x Width x Height _ in mtr)
3 MTR X 3 MTR X 4.5 MTR
Contact Us

Factory: Plot no- 4356, Road - E(end), Kansumra Road, GIDC phase - 3, Dared, Jamnagar, Gujarat, 361004, India