HAG Base Hot Boilers - 4 LACKS KCAL/HR

HAG Base Hot Boilers - 4 LACKS KCAL/HR
HAG Base Hot Boilers - 4 LACKS KCAL/HR
Product Code : HB 05
Product Description

HAG Base Hot Boilers - 4 LACKS KCAL/HR

 

  • This is indirect hot air boiler mainly used for air heating process requirement. Capacity starts from 100000 kcal/hour to

    2000000 kcal/hour& above at 250’C as per customer’s requirement.

  • This equipment consisting of 4 paths flew gas system.

  • Radiant path constructed from SS 410 of shell to shell and another 2nd, 3rd &5th pass constructed from ERW IS 1239 tubes.

  • Furnace made from MS structure and high aluminium bricks line, high grade CI casted fire bars equipment is fully insulated with high

    grade density glass wool.

  • System is controlled through the control panel with simulation of ID & FD fans maintain the air temperature and smoke temperature

    at prefix set value.

 

HOT AIR BOILER 4 LACKS KCAL HR –SOLID FUEL FIRE



  Model   Model_IV
  Product   HOT AIR BOILER
  Capacity   4 LACKS KCAL HR-
POWER   Centrifugal CA blower   30 HP
  Furnace Id Fan   7.5 HP
  Furnace Fd fan  2.0 HP
  Total
  39.5 HP
  Working temperature   100 –120 C
  Fuel consumption   220 kg hr - wood ( GCV 2400 )
  No of PASS   5 pass
  Dryer Efficiency   70 %
  Over all space require for dryer ( Length x Width x Height _ in mtr)   10. MTR X 4 MTR X 4.5 MTR
( ALL SPECIFICATION ALTERATION RIGHT RESERVE BY- OPTYTECH ENGINEERS)

 


HAG Base Hot Boilers - 4 LACKS KCAL/HR

 

  • This is indirect hot air boiler mainly used for air heating process requirement. Capacity starts from 100000 kcal/hour to

    2000000 kcal/hour& above at 250’C as per customer’s requirement.

  • This equipment consisting of 4 paths flew gas system.

  • Radiant path constructed from SS 410 of shell to shell and another 2nd, 3rd &5th pass constructed from ERW IS 1239 tubes.

  • Furnace made from MS structure and high aluminium bricks line, high grade CI casted fire bars equipment is fully insulated with high

    grade density glass wool.

  • System is controlled through the control panel with simulation of ID & FD fans maintain the air temperature and smoke temperature

    at prefix set value.

 

HOT AIR BOILER 4 LACKS KCAL HR –SOLID FUEL FIRE



  Model   Model_IV
  Product   HOT AIR BOILER
  Capacity   4 LACKS KCAL HR-
POWER   Centrifugal CA blower   30 HP
  Furnace Id Fan   7.5 HP
  Furnace Fd fan  2.0 HP
  Total
  39.5 HP
  Working temperature   100 –120 C
  Fuel consumption   220 kg hr - wood ( GCV 2400 )
  No of PASS   5 pass
  Dryer Efficiency   70 %
  Over all space require for dryer ( Length x Width x Height _ in mtr)   10. MTR X 4 MTR X 4.5 MTR
( ALL SPECIFICATION ALTERATION RIGHT RESERVE BY- OPTYTECH ENGINEERS)

 


Contact Us

Factory: Plot no- 4356, Road - E(end), Kansumra Road, GIDC phase - 3, Dared, Jamnagar, Gujarat, 361004, India